Power On: Use the main switch (0/I) located on the unit to power the device.
- Infrared Only: Best for gentle processing and deep conditioning.
- Warm Air Only: Used for drying or specific chemical processes.
- Combination: Accelerates processing time.
Problem 1: No Heat, But Fan Works
- Cause: Burnt heating element or thermal fuse.
- Solution: Unplug. The thermal fuse is located under the dome’s arm housing. Replace with a 121°C thermal fuse (part no. Wella 089134 – obsolete, but generic works).
Set Timer: Turn the mechanical timer clockwise to the desired minutes (max 60). Note: Do not force the timer counter-clockwise; this damages the gear mechanism.
Emergency Stop: Open the hood fully or turn the timer to "0."