Jungheinrich Eje 120 Error Code 4372 Top ^hot^ Now

For the Jungheinrich EJE 120, error code 4372 (often displayed as E4372) indicates an implausible analogue signal from the tiller head sensor. This fault typically causes the truck to disable hydraulic functions. Common Causes & Solutions

Sometimes, an insufficient power supply causes sensors to behave erratically.

Step 3 – Electrical Testing (Switch S4)