Heidenhain: Itnc 530 Error List
Error Messages
-
- Error 301: I/O error: Input/output device error.
- Error 302: Communication error: Communication error with external devices.
He re-read the list’s footnote for 4623: Note: Intermittent signal may indicate RF interference or ground loop.
- Check lubrication system. Dry ways cause massive friction.
- Incrementally jog the axis. If it moves roughly, call service.
- Check the motor holding brake (24V supply).
- Temporarily reduce
MP 2100(Maximum following error) to test, but do not run production.
- Cause: Emergency stop active, enable relay off, safety circuit open, or servo amplifier fault.
- Fix: Release E-stop, verify safety interlocks, check cabinet fuses and enable relay, clear amplifier faults and power-cycle if needed.